4.9.2

CANopen profile DS301

The available objects are defined according to communication profile DS301.

4.9.2.1 Communication objects (1000

hex

- 1200

hex

)

Index

Sub

Object

Description

Unit Access Type

0x1000

0

Device type

Device type and functionality

RO

U32

0x1001 0

Error

register

The Error Register is set to 1 (=generic error) if one of
the connected frequency inverters is in an error state.
In addition, it is monitored whether a registered
inverter goes missing. In this case, this register will
also be set.

RO

U8

0x1002 0

Status

register Status of the module

RO

U32

0x1003 ARR

Pre-defined error

Error signaled by an emergency object

U8

0

Number of errors

Number of errors;

0 deletes the error list

RW

U8

1

Error code

Error number

RO

U32

0x1005 0

COB-ID

SYNC

Identifier for SYNC messages (default 80h)

(see parameter (P161 [-01]))

RW

U32

0x1008

0

Device name

Device name

RO

STR

0x1009 0 Hardware

version

Hardware version

RO

STR

0x100A

0

Software version

Software version FI+CO

RO

STR

0x100C 0

Guard

time

Guard time (0=off)

(see parameter (P166 [-01]))

ms RW U16

0x100D

0

Life time factor

Life time = Life time factor * Guard time

(see parameter (P167))

RW

U8

0x1010 0 Store

parameters

With this object it is possible to permanently save
settings made by the user. To do this, the signature
“Save“ (lower case letters ASCII – MSB - 0x65 76 61
73 - LSB) must be written in Index 0x1010 Sub-index
1. The saving process runs in the background and is
confirmed with an SDO response telegram.

Caution: If the module ID is changed with the DIP
switches after saving a configuration, the saved
configuration will still be used. The default mapping
is restored with the object 0x1011.

RW

U32

0x1011 0

Restore default

parameters

With this object it is possible to restore parameters
saved by the user to the default settings. By writing
the signature "load" (lower case letters ASCII - MSB
0x64 0x61 0x6F 0x6C LSB) in Index 0x1011 Sub-
index 1, the standard factory settings will be loaded
after the following Power ON and every other Power
ON (until the next SAVE command).

(see parameter (P152))

RW

U32

0x1014 0

COB-ID

Emergency Object

Identifier Emergency Object

(80h+Node-ID)

RO

U32

0x1015

0

Inhibit time EMCY Minimum repeat time

ms

RW

U16

0x1017 0

Producer Heartbeat

time

Cycle time of the heartbeat function

(see Parameter (P166 [-02]))

ms RW U16

0x1018 REC

Identity object

General device information

U32

0

Largest sub-index Number of elements

RO

U8

1

Vendor ID

CiA-listed manufacturer code

RO

U32

2

Product code

Device version (product number)

RO

U32

3

Revision number

Software version and revision number (2x16 bit)

RO

U32

Advertising