NORD Drivesystems BU0260 User Manual

Page 55

Advertising
background image

4 Commissioning

BU 0260 GB

Subject to technical amendments

55

4.9.4

Frequency inverter objects (2000

hex

- 3005

hex

)

Index

Sub

Object

Description

Unit

Acc

Type

0x2000-
0x23E7

-

FI parameter

FI parameter

(see parameter (P165)):

0x3000 0 Largest

Subindex

Number of control word elements

RO

U8

0x3000

1

Control word

Control word (STW) FI 1

RW

U16

0x3000

2

Control word

Control word (STW) FI 2

RW

U16

0x3000

3

Control word

Control word (STW) FI 3

RW

U16

0x3000

4

Control word

Control word (STW) FI 4

RW

U16

0x3001 0 Largest

Subindex

Number of status word elements

RO

U8

0x3001

1

Status word

Status word (ZSW) FI 1

RO

U16

0x3001

2

Status word

Status word (ZSW) FI 2

RO

U16

0x3001

3

Status word

Status word (ZSW) FI 3

RO

U16

0x3001

4

Status word

Status word (ZSW) FI 4

RO

U16

0x3002 0 Largest

Subindex

Number of setpoint elements

RO

U8

0x3002

1

Setpoint 1

Setpoint 1 (SW1) FI 1

RW

U16

0x3002

2

Setpoint 2

Setpoint 2 (SW2) FI 1

RW

U16

0x3002

3

Setpoint 3

Setpoint 3 (SW3) FI 1

RW

U16

0x3002

4

Setpoint 1

Setpoint 1 (SW1) FI 2

RW

U16

0x3002

5

Setpoint 2

Setpoint 2 (SW2) FI 2

RW

U16

0x3002

6

Setpoint 3

Setpoint 3 (SW3) FI 2

RW

U16

0x3002

7

Setpoint 1

Setpoint 1 (SW1) FI 3

RW

U16

0x3002

8

Setpoint 2

Setpoint 2 (SW2) FI 3

RW

U16

0x3002

9

Setpoint 3

Setpoint 3 (SW3) FI 3

RW

U16

0x3002

10

Setpoint 1

Setpoint 1 (SW1) FI 4

RW

U16

0x3002

11

Setpoint 2

Setpoint 2 (SW2) FI 4

RW

U16

0x3002

12

Setpoint 3

Setpoint 3 (SW3) FI 4

RW

U16

0x3003 0 Largest

Subindex

Number of actual value elements

RO

U8

0x3003

1

Actual Value 1

Actual value 1 (IW1) FI 1

RO

U16

0x3003

2

Actual Value 2

Actual value 2 (IW2) FI 1

RO

U16

0x3003

3

Actual Value 3

Actual value 3 (IW3) FI 1

RO

U16

0x3003

4

Actual Value 1

Actual value 1 (IW1) FI 2

RO

U16

0x3003

5

Actual Value 2

Actual value 2 (IW2) FI 2

RO

U16

0x3003

6

Actual Value 3

Actual value 3 (IW3) FI 2

RO

U16

0x3003

7

Actual Value 1

Actual value 1 (IW1) FI 3

RO

U16

0x3003

8

Actual Value 2

Actual value 2 (IW2) FI 3

RO

U16

0x3003

9

Actual Value 3

Actual value 3 (IW3) FI 3

RO

U16

0x3003

10

Actual Value 1

Actual value 1 (IW1) FI 4

RO

U16

0x3003

11

Actual Value 2

Actual value 2 (IW2) FI 4

RO

U16

0x3003

12

Actual Value 3

Actual value 3 (IW3) FI 4

RO

U16

0x3004

0

Digital outputs

Control of digital outputs

RW

U16

0x3005 0 Digital

inputs

Status

of digital inputs

RO

U16


Advertising