NORD Drivesystems BU0260 User Manual

Page 54

Advertising
background image

Supplementary Manual CANopen for NORDAC SK 20E

54

Subject to technical amendments

BU 0260 GB

Index

Sub Object

Description

Unit Access Type

0x6049

Vl_velocity_deceleration

Speed

deceleration

0

Largest sub-index

Number of elements

RO

U8

1

Delta_speed

Delta speed

(see parameter

(P168 [-04, -08, -12, -16]))

rpm RW

U32

2

Delta_time

Delta

time

(see parameter

(P168 [-05, -09, -13, -17]))

S RW U16

0x60FD

Digital inputs profile
PDO data (00 0X 00 00)

0…15 =

Reserved

16

= Digital input 1 (ext. + int. modules)

17

= Digital input 2 (ext. + int. modules)

18

= Digital input 3 (ext. modules)

19

= Digital input 4 (ext. modules)

20…31 =

Reserved

RO U32

0x60FE

Digital outputs profile

0…15 =

Reserved

16

= Digital output 1 (ext. modules)

17

= Digital output 2 (ext. modules)

18…31 =

Reserved

RW U32