NORD Drivesystems BU0260 User Manual

Page 96

Advertising
background image

Supplementary Manual CANopen for NORDAC SK 20E

96

Subject to technical amendments

BU 0260 GB

These objects are stored with the aid of SDO transfers:

Map object 0x3000

CAN-ID

Data

Transmit

0x0600

0x23 00 1A 01 10 01 00 30

Set object 0x1A00 Sub-index 1 to object 0x3000 Sub-index 1 and 16 bit data width


Map object 0x3002

CAN-ID

Data

Transmit

0x0600

0x23 00 1A 02 10 03 02 30

Set object 0x1A00 Sub-index 2 to object 0x3002 Sub-index 3 and 16 bit data width


Number of mapping objects = 2, enter into Sub-index 0

CAN-ID

Data

Transmit

0x0600

0x2F 00 1A 00 02 xx xx xx

Receive

0x0580

0x60 00 1A 00 xx xx xx xx



Change communication parameters

Deactivation of Transmit PDO 1
In order to change the communication parameters, the Transmit PDO 1 which was prepared in the example
above must be deactivated.
To do this, the value 0x80000000 must be written into the communication object of the Transmit PDO1
(Transmit PDO communication parameter, Index 0x1800, Sub-index 01).

CAN-ID

Data

Transmit

0x0600

0x23 00 18 01 00 00 00 80

Receive

0x0580

0x60 00 18 01 xx xx xx xx



Setting the communication parameters for Transmit PDO1
In the object with the index 0x1800, Sub-index 1 to 3 (Transmit PDO communication parameter) the
communication parameters must now be written into the structure.
Here, Transmission Type 3 (synchronous transmission with each 3rd SYNC object) is defined.

TxPDO communication parameter, Index 0x1800

Sub-index

Value

Significance

0

3

Number of entries

1

0x0432

COB-ID used by PDO

2 3 Transmission

type

3 0 Inhibit

time


Sub-index 3: Inhibit time = 0

CAN-ID

Data

Transmit

0x0600

0x2B 00 18 03 00 00 xx xx

Receive

0x0580

0x60 00 18 03 xx xx xx xx


Advertising