4 Commissioning

BU 0260 GB

Subject to technical amendments

43

STW

SW1

SW2

SW3

DIs

In the following example of a VIPA control, the linking of the objects (status word and actual value) of FI 1 to
those of the CANopen master is illustrated.

4th frequency inverter

Actual value

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3001

4

Status

word

(ZSW)

1

0x3003 10

Actual value 1 (IW1)

2

0x3003 11

Actual value 2 (IW2)

3

0x3003 12

Actual value 3 (IW3)

3rd frequency inverter

Actual value

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3001

3

Status

word

(ZSW)

1

0x3003 7

Actual value 1 (IW1)

2

0x3003 8

Actual value 2 (IW2)

3

0x3003 9

Actual value 3 (IW3)

Actual PDO value

2nd frequency inverter

Actual value

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3001

2

Status

word

(ZSW)

1

0x3003 4

Actual value 1 (IW1)

2

0x3003 5

Actual value 2 (IW2)

3

0x3003 6

Actual value 3 (IW3)

1st frequency inverter

Actual value

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3001

1

Status

word

(ZSW)

1

0x3003 1

Actual value 1 (IW1)

2

0x3003 2

Actual value 2 (IW2)

3

0x3003 3

Actual value 3 (IW3)