7 i-100a: manufacturer software version, 8 i-100c: guard time, I−100a: manufacturer software version – Lenze EMF2178IB User Manual

Page 100: I−100c: guard time, Implemented canopen objects

Advertising
background image

Implemented CANopen objects

Overview
I−100A: Manufacturer software version

13

l

100

EDSMF2178IB EN 3.0

13.2.7

I−100A: Manufacturer software version

Index (hex)
0x100A

Name
Manufacturer’s software version

Subindex

Default
setting

Value range

Access

Data type

0

Module−specific

const

VS
(11
characters)

Display of the manufacturer’s software version of controller and communication module.

The manufacturer’s software version consists of a total of 11 characters:

ƒ

1st ... 5th character: The 10th to 14th character is read out of the software ID of the
standard device (C0200).
– 10th character: Major software version
– 11. character: Minor software version
– 12th ... 14th character: Power class of the standard device (see documentation of

the standard device)

ƒ

6th character: Use of an underscore ("_")

ƒ

7th ... 11th character: The 10th to 14th character is read out of the software ID of
the standard device (C1500).
– e.g. "20000" from the total "82ZAFU0B_20000" ID of the E82ZAFUC

communication module (CANopen)

13.2.8

I−100C: Guard time

Index (hex)
0x100C

Name
Guard time

Subindex

Default
setting

Value range

Access

Data type

0

0

0

...

65535 rw

U16

The guard time is indicated in milliseconds.

With the default setting of "0", "node guarding" is not supported.

"Node guarding" in the slave is activated if a value > "0" is selected for the "guard time" and
the "life time factor". The "guard time" indicates the time within which the RTRs from the
master are awaited.