Monitoring

Heartbeat Protocol

11

l

83

EDSMF2178IB EN 3.0

11

Monitoring

11.1

Heartbeat Protocol

)

Note!

ƒ

Only one monitoring function can be active:
– Heartbeat or node guarding.

ƒ

Heartbeat has priority over node guarding:
– If both functions are configured, the heartbeat settings will be active.

1

1

8

8

. . . .

. . . .

t

t

s

s

Indication

Heartbeat
Event

Indication

Indication

Request

Request

Indication

Indication

Indication

NMT-Master

NMT-Slave

Heartbeat
Producer
Time

Heartbeat
Consumer
Time

t = 0

t = 0

EMERGENCY

E82ZAFU009

CANopen objects for configuration

CANopen

Lenze

Index

Subindex

Designation

Code

Subcode

Description

I−1016

1

Consumer heartbeat time and COB−ID

C1869
C2369

Consumer heartbeat COB−ID

C1870
C2370

1

Consumer heartbeat time

I−1017

0

Producer heartbeat time

C1870
C2370

2

Producer heartbeat time

The "heartbeat producer" cyclically sends a heartbeat message to one or several
"heartbeat consumers".