Overview
I−1017: Producer heartbeat time

13

l

106

EDSMF2178IB EN 3.0

13.2.15

I−1017: Producer heartbeat time

Index (hex)
0x1017

Name
Producer heartbeat time

Subindex

Default
setting

Value range

Access

Data type

0

0

0

...

65535 rw

U32

The heartbeat telegram will be sent automatically if a value > "0" is entered in I−1017. The
cycle time corresponds to the entered value in milliseconds.

"Node guarding" is deactivated when the "heartbeat time" is active.

13.2.16

I−1018: Module device description

Entry of vendor ID

Index (hex)
0x1018

Name
Module device description

Subindex

Default
setting

Value range

Access

Data type

0

Module device description −

Module−specific

ro

Identity

...

4

Subindices

Subindex

Meaning

0

Highest subindex

1

Vendor ID = ID assigned to Lenze by the organisation "CIA"

2

Product code

3

Revision number

4

Serial number

13.2.17

I−1029: Error behaviour

Index (hex)
0x1029

Name
Error characteristics

Subindex

Default
setting

Value range

Access

Data type

0

No. of error classes

0

...

255 ro

U8

1

Communication error

0

...

2 rw

U8

Subindex 1

Value of
subindex 1

Meaning

0

Status change to "Pre−operational"

1

No status change

2

Status change to "Stopped"

Here, the response to communication errors (node guarding, heartbeat) can be set under
subindex 1.