Process data transfer – Lenze EMF2178IB User Manual

Page 53

Advertising
background image

Process data transfer

Cyclic process data objects

Process data signals of Lenze controllers

9

l

53

EDSMF2178IB EN 3.0

Device control word AIF−CTRL for 8200 vector (C0135, index 0x5F78)

Bit

Assignment (Lenze setting)

Set under
C0410/...

C0001 = 3 with C0007

£ 51

C0001 = 3 with C0007 > 51

0 / 1

JOG values

Freely configurable

1
2

Bit 1

0

0

0

00 = C0046 active

0

1

01 = NSET1−JOG1 (C0037) active

1

0

10 = NSET1−JOG2 (C0038) active

1

1

11 = NSET1−JOG3 (C0039) active

2

Current direction of rotation

(DCTRL1−CW/CCW)

Freely configurable

3

0
1

Not active
Active

3

Quick stop (QSP)

(AIF−CTRL−QSP)

Quick stop (QSP)

(AIF−CTRL−QSP)

4

0
1

Not active
Active

0
1

Not active
Active

4

Stop ramp function generator

(NSET1−RFG1−STOP)

Freely configurable

5

0
1

Not active
Active

5

Ramp function generator input = 0

(NSET1−RFG1−0)

Freely configurable

6

0
1

Not active
Active

6

UP function motor potentiometer

(MPOT1−UP)

Freely configurable

7

0
1

Not active
Active

7

DOWN function motor potentiometer

(MPOT1−DOWN)

Freely configurable

8

8

Freely configurable

Freely configurable

9

9

Controller inhibit

(AIF−CTRL−CINH)

Controller inhibit

(AIF−CTRL−CINH)

10

0
1

Not active
Active

0
1

Not active
Active

10

External fault

(AIF−CTRL−TRIP−SET)

External fault

(AIF−CTRL−TRIP−SET)

11

0
1

Not active
Active

0
1

Not active
Active

11

Reset fault

(AIF−CTRL−TRIP−RESET)

Reset fault

(AIF−CTRL−TRIP−RESET)

12

0 −> 1 Edge from 0 to 1

0 −> 1 Edge from 0 to 1

12

Change over parameter set

(DCTRL1−PAR2/4)

Freely configurable

13

0
1

Not active
Active

13

Change over parameter set

(DCTRL1−PAR3/4)

Freely configurable

14

0
1

Not active
Active

14

DC injection brake

(MCTRL1−DCB)

Freely configurable

15

0
1

Not active
Active

15

Freely configurable

Freely configurable

16

Advertising