Parameter data transfer

Lenze parameter sets
Parameter sets for controller 93XX

10

l

72

EDSMF2178IB EN 3.0

10.2.2

Parameter sets for controller 93XX

The drive controllers 93XX feature up to four parameter sets for storage in the EEPROM for
each technology variant. An additional parameter set is located in the main memory of the
drive controller. This parameter set is referred to as "current" parameter set.

Addressing

ƒ

Only the current parameter set can be directly addressed via the bus.

ƒ

After power−on, parameter set 1 is automatically loaded into the current parameter
set.

ƒ

Before changing the parameters of parameter sets 2 ... 4, the parameter sets must
be activated.

)

Note!

Changes in the current parameter set are lost after switching off the drive
controller.
Code C0003 is used to store the current parameter set (see documentation of
the controller).