Codes – Lenze EMF2178IB User Manual

Page 123

Advertising
background image

Codes

Communication−relevant Lenze codes

14

l

123

EDSMF2178IB EN 3.0

C1850/C2350:
CAN node address

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1850

22725 =
0x58C5

1

1

[1]

99 FIX32

C2350

22225 =
0x56D1

This code serves to set the CAN node address of the communication module.

)

Note!

ƒ

If several CAN nodes are interconnected, their node addresses must differ
from each other.

ƒ

Node addresses > 99 can only be set via DIP switch(

33).

ƒ

All DIP switches 1 ... 7 = OFF (Lenze setting):
– When the device is switched on, the settings under code C1850/C2350

(node address) and C1851/C2351 (baud rate) are active.

– Code C1850/C2350 is an image of code C0009 of the basic device. Setting

C1850/C2350 has a direct effect on C0009.