1 8200 vector controller, 2 9300 servo plc / drive plc / ecs, 8200 vector controller – Lenze EMF2178IB User Manual

Page 81: 9300 servo plc / drive plc / ecs, Parameter data transfer

Advertising
background image

Parameter data transfer

Special features for parameter setting of the drive controller

8200 vector controller

10

l

81

EDSMF2178IB EN 3.0

10.6

Special features for parameter setting of the drive controller

10.6.1

8200 vector controller

The digital and analog input and output signals are freely configurable (see System
Manual 8200 vector; code C0410, C0412, C0417 and C0421).

10.6.2

9300 Servo PLC / Drive PLC / ECS

AIF control byte (C2120)/AIF status byte (C2121)

The controller and the EMF2178IB communication module are able to exchange control
and status information. For this purpose, a control byte and a status byte are made
available in the AIF protocol.

C2120:
AIF control byte

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C2120

22455 =
0x57B7

0

See table below

FIX32

Possible settings

Selection

Description

0

No command

1

Update codes 23XX and CAN reinitialisation

º reset node

2

Update codes C23XX

10

Reread C2356/1...4

11

Reread C2357

12

Reread C2375

13

Reread C2376 ... C2378

14

Reread C2382

16

1)

Update C7999 and C7998 including CAN reinitialisation

17

1)

Update C7999, mapping table of profile indices

18

1)

Update C7998, error list of emergency messages

32

1)

Reset error source, activate emergency messages

33 ... 62

1)

Error source 1 ... 30, activate emergency messages

1)

Value range is only valid for profile applications in a PLC

With the AIF control byte it is possible to read the codes C23XX saved in the 9300 Servo PLC,
Drive PLC and ECS into the communication module.

Execute command

How to accept the values in the communication module:

ƒ

Write the table value of the required command into the AIF control byte.

ƒ

Change the status of the MSB of the AIF control byte. The command is executed.

Advertising