9 i-100d: life time factor, 10 i-1010: store parameters, I−100d: life time factor – Lenze EMF2178IB User Manual

Page 101: 10 i−1010: store parameters, Implemented canopen objects

Advertising
background image

Implemented CANopen objects

Overview

I−100D: Life time factor

13

l

101

EDSMF2178IB EN 3.0

13.2.9

I−100D: Life time factor

Index (hex)
0x100D

Name
Life time factor

Subindex

Default
setting

Value range

Access

Data type

0

0

0

...

255 rw

U8

With the default setting of "0", "node guarding" is not supported.

The product of "guard time" and "life time factor" is important for the monitoring process.

13.2.10

I−1010: Store parameters

Parameter storage in the EEPROM

Index (hex)
0x1010

Name
Store parameters

Subindex

Default
setting

Value range

Access

Data type

0

Store parameters

0

...

2

32

− 1 ro

U8

1

U32

...

3

Subindices

Subindex

Authorisati
on

Description

Write

Read

0

ro

While writing, the 0x06010002 error
message occurs.

Supported subindex: 3

1

While writing, the 0x08000020 error
message occurs.

Reading of memory functions of all
parameters

2

Reading of memory functions of object
communication parameters

3

Reading of memory functions of
manufacturer−specific parameters
(Index 0x6000 ... 0x9FFF)

Bit assignment (reading)

U32

31

...

2

1

0

0

...

0

0/1

0/1

The following functions are controller−dependent. They are indicated by reading the bit
states 0 and 1.

Bits

Value

Meaning of the bit assignment

0

0

No automatic saving of parameters

1

Automatic saving of parameters

1

0

No saving of parameters on command

1

Saving of parameters on command

2 ... 31

0

Advertising