Codes

Communication−relevant Lenze codes

14

l

143

EDSMF2178IB EN 3.0

C1877/C2377:
Masks CAN−OUT2

This mask is used to skip one or several bits of the output PDO CAN−OUT2.

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1877

/1: CAN−OUT2.W1
/2: CAN−OUT2.W2
/3: CAN−OUT2.W3
/4: CAN−OUT2.W4

22698 =
0x58AA

65535

0

[1]

65535 FIX32

C2377

22198 =
0x56B6

For more information, please see the description of code C1876/C2376 (

^ 142).

C1878/C2378:
Masks CAN−OUT3

This mask is used to skip one or several bits of the output PDO CAN−OUT3.

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1878

/1: CAN−OUT3.W1
/2: CAN−OUT3.W2
/3: CAN−OUT3.W3
/4: CAN−OUT3.W4

22697 =
0x58A9

65535

0

[1]

65535 FIX32

C2378

22197 =
0x56B5

For more information, please see the description of code C1876/C2376 (

^ 142).

C1882/C2382:
Monitoring response

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1882

/1: response CAN−IN1
/2: response CAN−IN2
/3: response CAN−IN3
/4: response BUS−OFF
/5: response
life guarding event /
heartbeat event
/6: response Rx sync
monitoring

22693 =
0x58A5

/1:0
/2:0
/3:0
/4:0
/5:0
/6: 0

0

[1]

2 FIX32

C2382

22193 =
0x56B1

0: no response
1: Controller inhibit (CINH)
2: Quick stop (QSP)

Setting the response in the controller if the monitoring times have been exceeded (see
code C1857/C2357,

^ 131.).