2 description of the objects, Description of the objects, Operating modes – Lenze 931K User Manual

Page 105: Speed control description of the objects

Advertising
background image

Operating modes

Speed control

Description of the objects

9

l

105

KHB 13.0002−EN 4.1

9.2.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

6069

h

0 velocity_sensor_

actual_value

{1 inc/s}

VAR

INT32

RO

MAP

Reading−out of the speed
value directly on the encoder
system.
However, for determining
the actual speed the object
606C

h

should be used.

606B

h

0 velocity_demand_

value

{1 rpm}

VAR

INT32

RO

MAP

Current speed setpoint.
This value is affected by the
setpoint of the ramp
generator / the trajectory
generator.
If the position controller is
activated, the correction
speed of this controller is
added.

606C

h

0 velocity_actual_

value

{1 rpm}

VAR

INT32

RO

MAP

Reading−out of the actual
speed.

6080

h

0 max_motor_speed

32768

0

{1 rpm}

32768

VAR

UINT16

RW

MAP

Setting of the maximum
speed.
The speed setpoint is limited
to this value.

60FF

h

0 target_velocity

0

−2

31

{1 rpm}

2

31

−1

VAR

INT32

RW

MAP

Setting of the setpoint
selected for the ramp
generator.
The unit can be set via the
factor group.

Advertising