Appendix, Index table – Lenze 931K User Manual

Page 143

Advertising
background image

Appendix

Index table

10

l

143

KHB 13.0002−EN 4.1

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

60FF

h

0 target_velocity

0

−2

31

{1 rpm}

2

31

−1

VAR

INT32

RW

MAP

Setting of the setpoint
selected for the ramp
generator.
The unit can be set via the
factor group.

6410

h

0 motor_data

REC

UINT8

RO

Ċ

Reading−out of the motor
data.

3 iit_time_motor

2000

0

{1 ms}

10000

Ċ

UINT16

RW

Ċ

Setting of the time interval
for which the motor can be
fed with I

max

(index 6073

h

).

When this time has expired,
the motor is automatically
limited to the value set
under 6075

h

.

4 iit_ratio_motor

{1 ‰}

Ċ

UINT16

RO

MAP

Reading−out of the actual
utilisation ratio of the I

2

t

limitation.

10 phase_order

1

0

{1}

1

Ċ

UINT16

RW

MAP

Setting of the phase
sequence.
See ’angle encoder’ dialog
box in the SDC
parameterisation program.

0

Phase sequence: left

1

Phase sequence: right

11 resolver_offset_

angle

11360

−32767

{1 inc}

32767

Ċ

INT16

RW

MAP

Setting of the angle encoder
orientation with respect to
the permanent magnetic
field of the rotor.
See ’angle encoder offset
angle’ dialog box in the SDC
parameterisation program.
Conversion:

a = offset angle
× 32767/180°
= 11360 (with offset angle
= 62.4°)

Advertising
This manual is related to the following products: