6 emergency telegram, 1 telegram structure, Emergency telegram – Lenze 931K User Manual

Page 44: Telegram structure, Canopen communication

Advertising
background image

CANopen communication

Emergency telegram
Telegram structure

5

l

44

KHB 13.0002−EN 4.1

5.6

Emergency telegram

The drive controller monitors the functioning of its main components (including voltage
supply, power stage, angle encoder evaluation, technology slots). In addition, the motor
(temperature, angle encoder) and the limit switches are checked continuously. Incorrect
parameter settings can also cause error messages (division by zero, etc.).

If an error occurs, the error number is indicated on the display of the drive controller. If
several errors occur at the same time, the message with the highest priority (the lowest
number) is displayed.

5.6.1

Telegram structure

11 bits

4 bits

Error code

1001

h

1st byte

2nd byte

3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Identifier

Data

length

E0

E1

R0

00

00

00

00

00

The drive controller sends an emergency telegram if an error occurs. The identifier of this
message is composed of the identifier 80

h

and the node address of the drive controller

concerned.

The emergency telegram consists of eight bytes. The first and second byte contain the
error_code. In the third byte there is an additional error code (object 1001

h

). The fourth to

eighth byte are always set to zero.

Advertising