2 description of the objects, Description of the objects, Parameter setting – Lenze 931K User Manual

Page 71

Advertising
background image

Parameter setting

Loading and saving of parameter sets

Description of the objects

7

l

71

KHB 13.0002−EN 4.1

7.1.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

1010

h

0 store_parameters

ARR

UINT8

RO

Ċ

Not used.

1 save_all_

parameters

00000001

h

00000000

h

{1

h

}

65766173

h Ċ

UINT32

RW

Ċ

Acceptance of default
parameter set in application
parameter set.

00000000

h

Default parameter set is not
accepted.

65766173

h

Save

Default parameter set is
accepted.

1011

h

0 restore_parameters

ARR

UINT8

RO

Ċ

Query on the number of
possible objects.

1 restore_all_default

_parameters

00000001

h

00000000

h

{1

h

}

64616F6C

h Ċ

UINT32

RW

Ċ

Loading of the default
parameter set, only possible
if the power stage is
deactivated.
The CAN communication
parameters (node no., baud
rate and operating mode)
remain unchanged.

64616F6C

h

Load

Loading of default parameter
set.

00000001

h

Read access: Reset to default
values.

Advertising