Parameter setting

Conversion factors (factor group)
Description of the objects

7

l

74

KHB 13.0002−EN 4.1

7.2.2

Description of the objects

Object 6093

h

: position_factor

The position_factor object serves to convert all length units of the application from
position_units

to the internal unit of increments (65535 increments correspond to

1 revolution).

The numerator and the denominator have to be written separately into the drive
controller. It can, therefore, be necessary to bring the fraction to integers by appropriate
expansions.

The position_factor is calculated using the following formula:

position_factor + numerator

divisor

Example: The unit required at the output end is 1 rev (position_unit)

1. 1 inc = 1/65535 rev

2. Result:

Numerator = 1
Divisor = 65535