KHB 13.0002−EN 4.1

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

6071

h

0 target_torque

0

−32768

{motor_rated_torque/1000}

32768

VAR

INT16

RW

MAP

Input value for the torque
controller (torque control
operating mode).

6072

h

0 max_torque

2023

1000

{motor_rated_torque/1000}

65535

VAR

UINT16

RW

MAP

Input value for M

max

. The

value for index 6075

h

motor_rated_current must
be entered before this value
can be input.

6073

h

0 max_current

2023

0

{motor_rated_

current/1000}

65535

VAR

INT16

RW

MAP

Input value for I

max

.

The value for index 6075

h

motor_rated_ current must
be entered before this value
can be input.

6074

h

0 torque_demand_

value

{motor_rated_torque/1000}

VAR

INT16

RO

MAP

Reading−out of the setpoint
torque.

6075

h

0 motor_rated_

current

500

0

{1 mA}

VAR

UINT32

RW

MAP

Input value for I

r

(specified

on the motor nameplate).
The value must be smaller
than the rated controller
current.
If this index is changed, the
index 6073

h

max_current

also must be parameterised
again.

6076

h

0 motor_rated_

torque

1994

115

{0.001 Nm}

65535

VAR

UINT32

RW

MAP

Input value for M

r

(specified

on the motor nameplate).

6077

h

0 torque_actual_

value

{motor_rated_torque/1000}

VAR

INT16

RO

MAP

Actual torque value

6078

h

0 current_actual_

value

{motor_rated_current/1000}

VAR

INT16

RO

MAP

Reading−out of the actual
current value.

6079

h

0 DC_link_circuit_

voltage

0

{1 mV}

2

32

−1

VAR

UINT32

RO

MAP

Reading−out of the DC−bus
voltage.

607A

h

0 target_position

0

−2

31

{1 inc}

2

31

−1

VAR

INT32

RW

MAP

Entry of the target position
(absolute or relative entry,
see bit 6 of the control word).
The current settings for
speed, acceleration, braking
deceleration and type of the
travel profile must always be
taken into account.
The unit can be set via the
factor group.

607C

h

0 home_offset

0

−2

31

{1 inc}

2

31

−1

VAR

INT32

RW

MAP

Shift of zero position with
respect to home position.