3 parameterising of the speed control, Parameterising of the speed control, Commissioning – Lenze 931K User Manual

Page 61: Speed control parameterising of the speed control

Advertising
background image

Commissioning

Speed control

Parameterising of the speed control

6

l

61

KHB 13.0002−EN 4.1

6.2.3

Parameterising of the speed control

Before a control can be put into operation, it is often necessary to adapt the controller
parameters in order to ensure a dynamic and sufficiently damped operational
performance. The dimensioning of the controller parameters depends on the existing
system / the respective process and must be executed in advance.

The following short example shows the selection and subsequent parameterisation of the
speed control. In addition to the control parameters (K

p

, T

n

), the limit values required for

safe operation (maximum speed, maximum acceleration and maximum braking
deceleration) are specified.

No. Description

Identi

fier

Control

field

Comma

nd code

Index

Subin

dex

Data 1 Data 2 Data 3 Data 4

Data

length

Low

byte

High

byte

1

Definition of the operating mode
For the operating mode
(modes_of_operation), the speed
control (03) is selected.

601

5

2F

60

60

00

03

00

00

00

2

Setting of the speed controller (K

p

)

A gain (velocity_control_gain) of K

p

= 2

(corresponds to 200

h

) is selected.

601

6

2B

F9

60

01

00

02

00

00

3

Setting of the speed controller (T

n

)

A reset time (velocity_control_time) of
T

n

= 10 ms (corresponds to 2710

h

) is

selected.

601

6

2B

F9

60

02

10

27

00

00

4

Setting of the actual speed value filter
The time constant of the speed filter
(velocity_control_filter_time) is set to
0.5 ms (corresponds to 1F4

h

).

601

6

2B

F9

60

04

F4

01

00

00

5

Definition of the maximum speed
The maximum speed (end_velocity) is
set to 3000 rpm (corresponds to 0BB8

h

).

601

8

23

82

60

00

B8

0B

00

00

6

Definition of the maximum acceleration
The maximum acceleration
(profile_acceleration) is
20000 rev × 4096 inc/rev × 1/min/s
(corresponds to 4E20000

h

).

601

8

23

83

60

00

00

00

E2

04

7

Definition of the maximum braking
deceleration
The maximum deceleration
(profile_deceleration) is
20000 rev × 4096 inc/rev × 1/min/s
(corresponds to 4E20000

h

).

601

8

23

84

60

00

00

00

E2

04

Tab. 5

Parameterisation of a speed controller