Parameter setting – Lenze 931K User Manual

Page 80

Advertising
background image

Parameter setting

Current controller and motor adaptation
Description of the objects

7

l

80

KHB 13.0002−EN 4.1

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

2415

h

0 current_limitation

REC

INT8

RO

Ċ

Limitation von I

max

(independently of the
operating mode).
Torque−limited speed
operation is possible.

1 limit_current_

input_channel

00

h

00

h

{1

h

}

04

h Ċ

INT8

RW

Ċ

Setpoint source for the
limiting torque.

0

No limitation

1

AIN0

2

AIN2

3

RS232

4

CAN

2 limit_current

0

0

{1 mA}

100000

Ċ

INT32

RW

Ċ

l

Setpoint source RS232,
CAN: limitation of the
torque−proportional
current

l

Setpoint sources AIN0,
AIN1: Selection of the
scaling factor for the
analog inputs. The current
in mA corresponds to an
applied voltage of 10 V.

60F6

h

0 torque_control_

parameters

REC

UINT8

RO

Ċ

Reading−out of PI−controlled
current controller data.
The gain and the time
constant apply to both the
field−generating and the
torque−generating current
controller.

1 torque_control_

gain

256

0

{1}

32 × 256

Ċ

UINT16

RW

Ċ

Setting of the proportional
gain of the current controller.
From the SDC program:
K

p

= 1.0

Setting here:
1.0 × 256 = 256 (100

h

)

2 torque_control_

time

2000

100

{1

ms}

65500

Ċ

UINT16

RW

Ċ

Setting of the current
controller time constant.
From the SDC program:
T

n

= 2 ms

Setting here: 2 ms = 2000

ms