3 objects for pdo parameterisation, Objects for pdo parameterisation, Canopen communication – Lenze 931K User Manual

Page 26

Advertising
background image

CANopen communication

Process data transfer (PDO transfer)
Objects for PDO parameterisation

5

l

26

KHB 13.0002−EN 4.1

5.3.3

Objects for PDO parameterisation

Two transmit PDOs (TPDO) and two receive PDOs (RPDO) are available in the drive
controller. The different objects of the PDOs are identical.

1. Transmit PDO

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

1800

h

Transmit PDO1
Communication
Parameter

0 number_of_entries

00

h

{1

h

}

04

h

REC

UINT8

RO

Ċ

Maximum number of
supported subindexes.

03

h

3 subindexes are supported.

1 COB−ID_used_by_

PDO

00000181

h

00000181

h

{1

h

}

000001FF

h

Ċ

UINT32

RW

Ċ

Identifier of transmit PDO1,
(180

h

+ node address).

For processing, bits 30 and
31 must be set
(parameterisation of
mapping).

Bit no.

Value

0 − 10

x

11−bit identifier

11 − 28

0

The extended identifier
(bit 29) is not supported.
Each bit of this range must
be "0".

29

0

30

1

RTR of this PDO is not
permitted (unadjustable).

31

0

PDO is active

1

PDO is inactive

2 transmission_type

255

0

{1}

240, 254, 255

Ċ

UINT8

RW

Ċ

Setting of the transmission
mode

0

Function is switched off

n = 1 ... 240

By entering a value n, this
PDO is accepted with every
n−th sync.

n = 254, 255

Event−controlled
transmission mode

3 inhibit_time

0

0

{0.1 ms}

65535

Ċ

UINT16

RW

Ċ

Setting of the minimum
delay time between two
PDOs. The time can only be
changed if the PDO is not
active (subindex 1, bit 31 = 1)

Advertising
This manual is related to the following products: