Position control

Parameterising of the homing run

6

l

65

KHB 13.0002−EN 4.1

No. Description

Identi

fier

Control

field

Comma

nd code

Index

Subin

dex

Data 1 Data 2 Data 3 Data 4

Data

length

Low

byte

High

byte

1

State query (read)
Each change of the state must be
executed depending on the initial state.
After a state change you have to wait for
the state change being indicated in the
status word.

601

4

40

41

60

00

00

00

00

00

2

Control word: shut down
With the ’shut down’ command, the
state is adapted to
Ready_To_Switch_On.

601

6

2B

40

60

00

06

00

00

00

3

State query (read)
(Explanation see step 1)

601

4

40

41

60

00

00

00

00

00

4

Control word: switch on
With the switch on command, the state
is adapted to Switched_On.

601

6

2B

40

60

00

07

00

00

00

5

State query (read)
(Explanation see step 1)

601

4

40

41

60

00

00

00

00

00

6

Control word: enable operation
With the enable operation command,
the state is adapted to
Operation_Enable.
Voltage is now applied to the motor.
However, the homing run does not start
yet.

601

6

2B

40

60

00

0F

00

00

00

7

State query (read)
(Explanation see step 1)

601

4

40

41

60

00

00

00

00

00

8

Control word: Enable operation and
homing start
The enable operation and homing start
commands start the homing run.

601

6

2B

40

60

00

1F

00

00

00

9

State query (read)
At this point the homing run is
executed. Homing is completed when
bit 12 (homing attained) is set in the
status word.

601

4

40

41

60

00

00

00

00

00

10

Control word: disable voltage
This command switches off the drive
and sets it to the Switch_On_Disabled
state.

601

6

2B

40

60

00

00

00

00

00

Tab. 8

Execution of the homing run by means of the state machine