Operating modes – Lenze 931K User Manual

Page 118

Advertising
background image

Operating modes

Synchronous position selection
Functional description

9

l

118

KHB 13.0002−EN 4.1

No.

Event

CAN object

1

Generation of sync messages

2

Request of IP operating mode

6060

h

, modes_of_operation = 07

3

Waiting for the operating mode being reached

6061

h

, modes_of_operation_display = 07

4

Reading−out of the current actual position

6064

h

, position_actual_value

5

Writing−back as the current set position

60C1_01

h

, ip_data_position

6

Start of the interpolation

6040

h

, control word, enable_ip_mode

7

Acknowledgement through the drive controller

6041

h

, status word, ip_mode_active

8

Change of the current set position according to
trajectory

60C1_01

h

, ip_data_position

When the synchronous travel has been completed, further evaluation of position values
can be suppressed by deleting the enable_ip_mode bit. It is then possible to switch to
another operating mode if required.

Interpolation interruption in the event of errors

If a running interpolation (ip_mode_active is set) is interrupted by an error occurring in the
drive controller, the drive first responds in the way specified for the respective error (e.g.
cancelling of the controller enable and change to the switch_on_disables state).

In this case the interpolation can only be continued by switching on the IP parameters once
more because the drive controller must again reach the operation_enable state which
deletes the ip_mode_active bit.