Conversion factors (factor group)

7.2.1

Overview

Drive controllers are used in numerous applications, for instance as direct drives, with
downstream gearboxes, for linear drives, etc.

To enable simple parameterisation for all these different applications, the drive controller
can, by means of the factory group, be parameterised in such a way that the user can enter
or read out all quantities (e.g. the speed) directly on the drive in the units desired (e.g.
position values in millimetres and speeds in millimetres per second in the case of a linear
axis).

The drive controller then converts the entries to internal units by means of the factor group.
For every physical quantity (position, speed and acceleration) there is a conversion factor
for adapting the user units to the own application.

The units set by the factor group are generally designated as positions_units, speed_units
or acceleration_units.

The below diagram illustrates the function of the factor group.

Factor Group

position_units

speed_units

acceleration_units

position_factor

position_polarity_flag

velocity_polarity_flag

velocity_encoder_factor

acceleration_factor

increments (inc)

1 rpm

1 rpm/256s

±1

±1

±1

±1

0

2

3

4

1

931e_414

Fig. 10

Factor group

0 User units

1 Controller−internal units

2 Position

3 Speed

4 Acceleration