2 description of the objects, Description of the objects, Canopen communication – Lenze 931K User Manual

Page 46: Emergency telegram description of the objects

Advertising
background image

CANopen communication

Emergency telegram
Description of the objects

5

l

46

KHB 13.0002−EN 4.1

5.6.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

1001

h

0 error_register

VAR

UINT8

RO

MAP

Reading−out of the error
register.

Bit no.

Meaning

0

generic error

An unspecified error has
occurred (flag is set for every
error message).

1

current

2

voltage

3

temperature

4

communication error

Communication error (CAN
overrun).

5

device profile specific

6

reserved

7

manufacturer specific

Manufacturer−specific error.

1003

h

0 pre_defined_error_

field

0

0

{1}

255

ARR

UINT8

RW

Ċ

Reading−out of the number
of stored error messages.
When an error has occurred,
the error has to be
acknowledged to activate
the power stage (bit 7,
control word index 6040

h

).

0

Memory is cleared

1 standard_error_

field_0

Ċ

UINT32

RO

Ċ

Reading−out of last error
message

...

4 standard_error_

field_3

Ċ

UINT32

RO

Ċ

Reading−out of error
message

1014

h

0 COB−ID_emergency

_message

00000081

h

00000000

h

{1

h

}

00000081

h

VAR

UINT32

RW

Ċ

Emergency object identifier,
080

h

+ node address

Bit no.

Value

0 − 10

x

11−bit identifier

11 − 28

0

The extended identifier
(bit 29) is not supported.
Each bit of this range must
be "0".

29

0

30

0

Reserved

31

0

Emergency object is valid

1

Emergency object is invalid