2 description of the objects, Description of the objects, Operating modes – Lenze 931K User Manual

Page 114

Advertising
background image

Operating modes

Synchronous position selection
Description of the objects

9

l

114

KHB 13.0002−EN 4.1

9.5.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

60C0

h

0 interpolated_

submode_select

−2

−2

{}

−2

VAR

INT16

RW

MAP

Selection of the interpolation
type.

−2

Linear interpolation without
buffer

60C1

h

0 interpolated_data_

record

REC

UINT8

RO

Ċ

Reading−out of the data
record.
The record consists of the
position value
(ip_data_position) and the
optional control word
(ip_data_controlword).

1 ip_data_position

0

−2

31

{1 inc}

2

32

−1

Ċ

INT32

RW

MAP

Entry of the absolute
position value.

60C2

h

0 interpolated_time_

period

REC

UINT8

RO

Ċ

Reading−out of the
synchronisation interval.

1 ip_time_units

10

8
80

{1 ms}

{0.1 ms}

40

400

Ċ

UINT8

RW

MAP

Parameterisation of the
synchronisation interval.

2 ip_time_index

−3

−4

{1}

−3

Ċ

INT8

RW

MAP

Selection of the interval unit
(ms or 1/10 ms).

−3

ip_time_units in 1 ms

−4

ip_time_units in 0.1 ms

Advertising