Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

6060

h

0 modes_of_

operation

1

{1}

7

VAR

INT8

RW

MAP

Selection of the operating
mode

1

Position control with
positioning operation

3

Speed control with setpoint
ramp

4

Torque control with setpoint
ramp

6

Homing

7

Synchronous position
selection

6061

h

0 modes_of_

operation_display

VAR

INT8

RO

MAP

Display of the operating
mode.
If operation via CANopen is
not possible, an internal
operating mode is displayed.

−1

Unknown operating mode /
change of operating mode

1

Position control with
positioning operation

2

Speed control without
setpoint ramp

3

Speed control with setpoint
ramp

4

Torque control with setpoint
ramp

6

Homing

7

Synchronous position
selection

−11

Internal positioning
operation

−12

Internal speed control
without setpoint ramp

−13

Internal speed control with
setpoint ramp

−14

Internal torque control

−15

Internal position control

6062

h

0 position_demand_

value

−2

31

{1 inc}

2

31

−1

VAR

INT32

RO

MAP

Reading−out of the position
setpoint.
This value is supplied to the
position controller by the
trajectory generator.

6063

h

0 position_actual_

value

−2

31

{1 inc}

2

31

−1

VAR

INT32

RO

MAP

Reading−out of the actual
position.
The unit can be set via the
factor group.

6064

h

0 position_actual_

value

−2

31

{position units}

2

31

−1

VAR

INT32

RO

MAP

Reading−out of the actual
position.

Advertising