CANopen communication

Heartbeat telegram
Boot−up telegram

5

l

50

KHB 13.0002−EN 4.1

5.8

Boot−up telegram

After the supply voltage has been switched on or after a reset, the drive controller sends
the boot−up telegram indicating that the initialisation phase is completed. The controller
then is in the NMT state pre−operational.

5.8.1

Telegram structure

11 bits

4 bits

User data (1 byte)

1st byte

2nd byte

3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Identifier

Data

length

0

The structure of the boot−up telegram is almost identical to the structure of the heartbeat
telegram.

The boot−up telegram is also sent with the identifier 700

h

+ node address. The data length

is 1.

The only difference is that a zero is sent instead of the NMT state. For boot−up telegrams,
too, the sending device expects – depending on the error management setting – the
receipt of the telegram to be acknowledged by the other bus devices.