background image

Appendix

Index table

10

l

129

KHB 13.0002−EN 4.1

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

1801

h

Transmit PDO2
Communication
Parameter

0 number_of_entries

00

h

{1

h

}

04

h

REC

UINT8

RO

Ċ

Maximum number of
supported subindexes

03

h

3 subindexes are supported.

1 COB−ID_used_by_

PDO

00000281

h

00000281

h

{1

h

}

000002FF

h

Ċ

UINT32

RW

Ċ

Identifier of transmit PDO2,
(280

h

+ node address).

For processing, bits 30 and
31 must be set
(parameterisation of
mapping).

Bit no.

Value

0 − 10

x

11−bit identifier

11 − 28

0

The extended identifier
(bit 29) is not supported.
Each bit of this range must
be "0".

29

0

30

0

RTR of this PDO is permitted
(Lenze)

1

RTR of this PDO is not
permitted (unadjustable)

31

0

PDO is active

1

PDO is inactive

2 transmission_type

255

0

{1}

240, 254, 255

Ċ

UINT8

RW

Ċ

Setting of the transmission
mode

0

Function is switched off

n = 1 ... 240

By entering a value n, this
PDO is accepted with every
n−th sync.

n = 254, 255

Event−controlled
transmission mode

3 inhibit_time

0

0

{0.1 ms}

65535

Ċ

UINT16

RW

Ċ

Setting of the minimum
delay time between two
PDOs. The time can only be
changed if the PDO is not
active (subindex 1, bit 31 = 1)

Advertising