Device control

State diagram

States of the drive controller

8

l

93

KHB 13.0002−EN 4.1

8.1.3

States of the drive controller

State

Meaning

Not_Ready_To_Switch_On

The drive controller executes a self−test. The CAN communication is not yet
working.

Switch_On_Disabled

The drive controller has completed the self−test. CAN communication is
working.

Ready_To_Switch_On

The drive controller waits until the digital input DIN9 "controller enable" is at
24 V. (Controller enable logic "digital input and CAN").

Switched_On

The power stage can be switched on.

Operation_Enable

1

)

Voltage is applied to the motor and the motor is controlled according to the
operating mode.

Quick_Stop_Active

1

)

The quick stop function is executed (see: quick_stop_option_code). Voltage is
applied to the motor and the motor is controlled according to the quick stop
function.

Fault_Reaction_Active

1)

An error has occurred. Critical errors cause the immediate change to the fault
state. For all other errors, the action selected in the
fault_reaction_option_code is executed. Voltage is applied to the motor and
the motor is controlled according to the fault reaction function.

Fault

An error has occurred. The motor is de−energised.

Tab. 12

States of the drive controller

1)

The power stage is switched on