MAINTENANCE AND SERVICING

Service Intervals

Refer to the illustrations on the following pages to identify the various locations that require lubrication and
servicing. Illustrations are organized by the frequency of service that is required.

IMPORTANT:
Unless otherwise specified, use High Temperature Extreme Pressure (EP2) Performance with 1% Maximum
Molybdenum Disulphide (NLGI Grade 2) Lithium Base.

Knife: Except in sandy conditions.

Figure 6.20: Every 10 Hours or Daily

Knifehead:

NOTE:
To prevent binding and/or excessive wear caused by
knife pressing on guards, do NOT over grease the
knifehead (A). Only, one to two pumps with a mechanical
grease gun (do NOT use an electric grease gun) is
required. If more than six to eight pumps of the grease
gun are required to fill the cavity, replace the seal in the
knifehead. Refer to

Removing Knifehead Bearing

.

NOTE:
Check for signs of excessive heating on first few guards
after greasing. If required, relieve pressure by pressing
check-ball in grease fitting.

Figure 6.21: Every 25 Hours

A - Knifehead (Single Knife (1 PLC) (Double Knife - 2 PLCS)