6reel endshields, Reel endshields, 6 reel – MacDon D65 SP DHOM User Manual

Page 230: 6 reel endshields

Advertising
background image

MAINTENANCE AND SERVICING

24. Tighten clamp (A) with modified channel lock pliers (B)

so that finger pressure will NOT move clamp.

IMPORTANT:
Over-tightening clamp may result in breakage.

Figure 6.197: Installing Clamp

25. Re-attach channels (C) to support (A) with screws (B)

and nuts. Torque screws to 32 lbf·ft (43 N·m).

26. Reinstall any fingers (D) that were removed with

screws (E). Refer to

Installing Plastic Fingers, page

207

.

Figure 6.198: Support

Figure 6.199: Opposite Support

6.8.6

Reel Endshields

The reel endshields and supports do not require regular maintenance but should periodically be checked for damage
and loose or missing fasteners. Endshields or supports that are slightly dented or deformed may be repaired.
Severely damaged components should be replaced.

Reel endshields can be attached to either end of the reel.

169899

218

Revision A

Advertising