Page b-2, Page b-4 – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 10

Advertising
background image

Publication 2098-DU003B-EN-P — September 2006

6

Ultra3000 Digital Servo Drive Installation Manual

Page B-2

Replace notes 6 and 7 in the Ultra3000 Interconnect Diagram Notes
with the ones shown below. The new versions include information
regarding the placement of ac line filters and routing of wires.

Page B-4

Replace the interconnect diagram on page B-4 with the one shown
below. The new diagram changes the recommended wiring of input
fusing, ac line filter, and contactor.

Figure B.2
Typical Power Wiring of Ultra3000 System
(2098-DSD-030x-xx
)

Note:

Information:

6

May be used to maintain power to logic section of drive and status LED indicators when main ac input power is removed. A separate ac line
source may be used if voltage is between 88-265V ac (rms) on 2098-DSD-xxx (230V drives) or 207-528V ac (rms) on 2098-DSD-HVxxx (460V
drives). In this configuration, a separate line filter for logic power may be required.

7

Place the ac (EMC) line filter as close to the drive as possible and do not route very dirty wires in wireway (refer to Establishing Noise Zones, on
page 1-13). If routing in wireway is unavoidable, use shielded cable with shields grounded to the drive chassis and filter case. For ac line filter
specifications, refer to AC Line Filter Specifications in Appendix A.

TB1

U

V

W

DC+

DC-

L1

L2/N

L1 AUX

L2/N AUX

L2/N

L1

CN1

43

44

TB2

1

2

3

43

44

CN1

43

44

Ultra3000

Digital Servo Drive

2098-DSD-030x-xx

Note 13

AC Input Power
Connections

Motor Power
Connections

Single-phase

AC Line Filter

Note 7

Input Fusing *

Note 4, 5

Single-phase Input

100-240V ac (rms)

Fused Disconnect

or Circuit Breaker *

Note 1

Isolation

Transformer *

Note 2

Chassis

Bonded Cabinet

Ground Bus *

Terminal
Blocks *

Note 3

To additional

Ultra3000 drive.

Three-phase

Motor Power

Connections

Note 12

Cable Shield
Clamp
Note 9

* Indicates User Supplied Component

STOP *

START *

CR1 *

CR1 *

CR1 *

M1 *

Refer to Attention statement (Notes 10, 11)

N.O. Relay Output+

N.O. Relay Output-

Note 20

24V dc

Note 6

M1 *

Note 8

External Passive
Shunt Connections

Single-phase AC Line

50/60 Hz

Input Fusing *

Note 4, 5

Advertising
This manual is related to the following products: