2-38

Ultra3000 Connector Data

Analog ILIMIT Input

The ILIMIT input specifies to the drive if the drive output current
should be limited. If the ILIMIT input is not connected, current is not
limited. A 10 bit A/D converter digitizes the signal. The configuration
of the ILIMIT input is shown in Figure 2.35.

The input range is 0 to 10V, and the drive current is limited inversely
proportional to the input voltage. A +10V input corresponds to no
current limiting, and a 0V input prevents any drive current.

Figure 2.35
Analog ILIMIT Input Configuration

The following table provides a description of the analog ILIMIT input
specifications.

10k

Ω

20k

Ω

20k

Ω

0.01

μF

+15 V

ILIMIT

Ultra3000 Drive

Parameter

Description

Minimum

Maximum

Resolution

Number of states that the input signal is divided into
which is 2

(to the number of bits)

.

10 bits

Input
Impedance

Open circuit impedance measured between the input
and analog common.

10 k

Ω

Input Signal
Range

Voltage applied to the input

0V

+10V

Offset Error

Deviation from the correct value expected from
analog-to-digital conversion when 0V is applied to the
input.

50 mV

Gain Error

Deviation of the transfer function from unity gain,
expressed in a percent of full scale.

1%

Propagation
Delay

Delay from the input to the firmware-accessible
registers.

100

μS