Publication 2098-DU003B-EN-P — September 2006

Ultra3000 Digital Servo Drive Installation Manual

5

Page A-4

Add the attention statement (below) to the Ultra3000 (460V) Power
Specifications table on page A-4. The table didn’t change, however,
the warning applies to all Ultra3000 drives.

Ultra3000 Drive (460V) Power Specifications

2098-DSD-HV030x-xx, -HV050x-xx, -HV100x-xx, -HV150x-xx, and -HV220x-xx

Specification

Description

2098-DSD-HV030

2098-DSD-HV050

2098-DSD-HV100

2098-DSD-HV150

2098-DSD-HV220

AC Input Voltage

(1) (2)

230...480V rms
Three-phase

AC Input Frequency

47...63 Hz

Main AC Input Current

(3) (4)

460V ac (rms) Nom
460V ac (rms) Max inrush

4 A
6 A

7 A
6 A

14 A
6 A

20 A
6 A

28 A
6 A

Auxiliary AC Input Current

230V ac (rms) Nom
360V ac (rms) Nom
480V ac (rms) Nom
230V ac (0-pk) Max inrush

(5)

480V ac (0-pk) Max inrush

(5)

0.55 A
0.35 A
0.25 A
47 A
68 A

Continuous Output Current (0-pk)

7 A

11 A

23 A

34 A

47 A

Intermittent Output Current (0-pk)

14 A

22 A

46 A

68 A

94 A

Bus Capacitance

470 μF

705 μF

940 μF

1880 μF

Internal Shunt Resistance

120

Ω

40

Ω

25

Ω

20

Ω

Shunt On

800V dc

Shunt Off

750V dc

Bus Overvoltage

810V dc

Internal Shunt

Continuous power
Peak power

100 W
5.3 kW

200 W
16 kW

200 W
25.6 kW

400 W
32 kW

External Shunt

Resistance (-0/+5%)
Continuous power
Peak power

120

Ω

3 kW
5.3 kW

40

Ω

10 kW
16 kW

25

Ω

15 kW
25.6 kW

20

Ω

22 kW
32 kW

Energy Absorption Capability

230V ac input with 230V motor
230V ac input with 460V motor
460V ac input

15 J
129 J
55 J

22 J
194 J
82 J

29 J
259 J
109 J

59 J
517 J
219 J

Continuous Power Output

230V ac input
460V ac input

1.5 kW
3.0 kW

2.5 kW
5.0 kW

5.0 kW
10 kW

7.5 kW
15 kW

11 kW
22 kW

(1)

Specification is for nominal voltage. The absolute limits are ±10%, or 207...528V rms.

(2)

The 2098-DSD-HVxxx-xx drives can be powered with 230-240 V rms in order to be used in conjunction with motors designed for 230V operation. In such cases, the voltage
levels used for shunting and DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor.

(3)

The 2098-DSD-HVxxx -xx (460V) drives are limited to three contactor cycles per minute.

(4)

Power initialization requires a short period of inrush current (processor controlled via soft start circuitry). Dual element time delay (slow blow) fuses are recommended
(refer to Fuse Specifications on page 6-8).

(5)

400

μs half wave sine.

ATTENTION

The inrush current-limiting circuitry is limited in the number of
power cycles it can withstand within a set period of time. If you
exceed these limitations, the circuitry will be damaged.