Ultra family external shunt module specifications – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 150

Advertising
background image

Publication 2098-IN003E-EN-P — April 2004

A-12

Specifications and Dimensions

Ultra Family External Shunt Module Specifications

The following external shunt modules are compatible with the
Ultra3000 drives with regenerative loads that exceed the capacity of
the internal shunt resistor.

1

Bussmann part number.

2

LittelFuse

®

part number.

3

Bonitron part number. For more information contact:

Bonitron, Inc.

521 Fairground Court,

Nashville, TN 37211

Tel: (615) 244-2825

www.BONITRON.com

Ultra3000 Drives

Shunt Module
Catalog Number

Specifications

Fuse Replacement

Drive
Voltage
VAC

Resistance
Ohms

Peak
Power
kW

Peak
Current
Amps

Continuous
Power
Watts

Shipping
Weight
kg (lbs)

2098-DSD-005, 010,
and 020

2090-UCSR-A300

230

36

4.0

10.5

300

1.51 (3.3)

2098-DSD-030

9101-1183

30

5.9

14.0

200

CCMR-4-½

2

2098-DSD-075 and
150

2090-UCSR-P900

18

10

23.3

900

4.08 (9.0)

FWP-10A14F

1

2098-DSD-HV030
and -HV050

2090-SR120-09

460

120

5.3

6.7

3.63 (8.0)

FWP-2.5A14F

1

2098-DSD-HV100

2090-SR040-09

40

16

20.0

FWP-5A14F

1

2090-SR040-18

40

20.0

1800

8.6 (19.0)

FWP-10A14F

1

2098-xxx-HV150

M3575R-H27B0,C

3

25-31

25.6

31.0

900

11.3 (25.0)

N/A

M3575R-H27BF,C

3

1800

N/A

2098-xxx-HV220

M3575R-H33BF,C

3

20-25

32.0

36.0

3600

12.7 (28.0)

N/A

Advertising