Ultra3000 power specifications – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 140

Advertising
background image

Publication 2098-IN003E-EN-P — April 2004

A-2

Specifications and Dimensions

Ultra3000 Power
Specifications

The following sections provide power specifications for the Ultra3000.

Ultra3000 (230V) Power Specifications

The table below lists general power specifications and requirements
for the Ultra3000 230V drives (2098-DSD-005x-xx, -010x-xx, and
-020x-xx).

1

Specification is for nominal voltage. The absolute limits are ±10%, or 88-265V

rms

.

2

The 2098-005x-xx, -010x-xx, and -020x-xx (230V) drives are limited to one contactor cycles per two minutes.

3

Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are
recommended (refer to Fuse Specifications on page A-5).

Specification

Description

2098-DSD-005

2098-DSD-010

2098-DSD-020

AC Input Voltage

1

100-240V

rms

Single Phase

AC Input Frequency

47 - 63 Hz

AC Input Current

2, 3

Nominal

Maximum inrush (230V ac input)

5A

rms

100A (0-peak)

9A

rms

100A (0-peak)

18A

rms

100A (0-peak)

Continuous Output Current

2.5A (0-peak)

5A (0-peak)

10A (0-peak)

Intermittent Output Current

7.5A (0-peak)

15A (0-peak)

30A (0-peak)

Bus Capacitance

1410 μF

1880 μF

1880 μF

Internal Shunt Resistance

N/A

N/A

N/A

Shunt On

N/A

N/A

N/A

Shunt Off

N/A

N/A

N/A

Bus Overvoltage

400V dc

400V dc

400V dc

Energy Absorption Capability

115V ac input

230V ac input

93 Joules

38 Joules

125 Joules

51 Joules

Continuous Power Output

115V ac input

230V ac input

0.25 kW

0.5 kW

0.5 kW

1.0 kW

1.0 kW

2.0 kW

IMPORTANT

Only the 2098-DSD-005, -010, and -020 models
support an auxiliary +5V logic supply since an
auxiliary AC input is not available. Refer to Auxiliary
5V Logic Supply
on page 2-26 for more information.

Advertising
This manual is related to the following products: