Figure 2.54 shows the configuration of the AX Auxiliary Encoder Input
channel. The BX and IX channels have the same configuration.

Note: CW pulses are only counted when the CCW input is low, and

CCW pulses are only counted when the CW input is low.

Figure 2.54
Auxiliary Encoder Input Configuration

Note: For single-ended connections, the negative terminals (CN1 pins

5 and 7) should be left disconnected, and the signal connections
should be made to CN1 pins 4 and 6.

The following table provides a description of the auxiliary encoder
interface.

10k

Ω

5k

Ω

1k

Ω

1k

Ω

+ 5 V

+ 5 V

56 pF

COMMON

COMMON

COMMON

AX +

AX -

56 pF

10k

Ω

Ultra3000 Drive

Parameter

Description

Minimum

Maximum

ON State

Input Voltage

Input voltage difference between the + input
and the - input that is detected as an ON
state.

+1.0V

+7.0V

OFF State

Input Voltage

Input voltage difference between the + input
and the - input that is detected as an OFF
state.

-1.0V

-7.0V

Common Mode

Input Voltage

Voltage between an input and logic ground.

-7.0V

+12.0V

Signal Frequency

Frequency of the AX or BX signal inputs.
Count frequency is 4 times this frequency for
A/B type inputs, and equal to this frequency
for Step/Dir and CW/CCW type inputs.

2.5 MHz

Pulse Width

Time interval that a Step/Dir type input or
CW/CCW type input must remain in a single
state for detection.

200 nS

Setup Time

Time interval that the Direction, CW, or CCW
must be stable before the corresponding
Step, CCW, or CW signal changes state.

200 nS