Ultra3000 Connector Data

Figure 2.31
Drive Output Connected to an Active Low Input using a Switch/Relay

Figure 2.32
Drive Output Connected to an Active Low Input using an Opto-Isolator

Figure 2.33
Drive Output Connected to an Active High (sinking) Input

3.3k

Ω

Ultra3000 Drive Output

IOCOM

Ultra3000 Drive Input

IOPWR

IOCOM

Solid State

Relay

IOPWR

3.3k

Ω

Ultra3000 Drive Output

IOCOM

Ultra3000 Drive Input

IOPWR

IOCOM

IOPWR

1k

Ω

Ultra3000 Drive Output

IOCOM

IOPWR

1k

Ω

IOCOM

IOCOM

CN1-27 or -28