Control string examples (120v ac) – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 170

Advertising
background image

Publication 2098-IN003E-EN-P — April 2004

B-16

Interconnect Diagrams

Control String Examples
(120V ac)

This section provides information to assist you in using the
configurable Drive Ready output in a control string with 120V ac input
voltage. Refer to Figure 2.26 in the chapter Ultra3000 Connector Data
for more information on the digital relay output.

The 120V ac control string wired to the Ultra3000 (2098-DSD-005x-xx,
-010x-xx, or -020x-xx) drives is shown in the figure below.

Figure B.16
120V ac Single-Phase Control String Example

ATTENTION

!

Implementation of safety circuits and risk assessment
is the responsibility of the machine builder. Please
reference international standards EN1050 and EN954
estimation and safety performance categories. For
more information refer to Understanding the
Machinery Directive
(publication SHB-900).

CN1

Ultra3000

120V AC

50/60 Hz

STOP

START

CR1

CR1

CR1

M1

Refer to Attention statement above

CR2

43

44

3

2

CR2

24V DC

M1

Fuse

Block

Single-Phase

AC Line

50/60 Hz

L1

L2/N

N.O. Relay Output+

N.O. Relay Output-

Aux Logic Power In +5V

Aux +5V Common

From CN1 Breakout Board
with 24V to 5V Aux Power
Converter (2090-U3CBB-DM

xx)

Note 20

Note 21

Advertising
This manual is related to the following products: