Publication 2098-IN003E-EN-P — April 2004

Interconnect Diagrams

B-5

The Ultra3000 (2098-DSD-075x-xx and -150x-xx) power wiring with
24V dc control string (non-SERCOS drives only) is shown in the figure
below. For the control string diagram with 120V ac input refer to
Figure B.18.

For SERCOS drives, input line contactor is part of the PLC program
and output control.

Figure B.3
Typical Power Wiring of Ultra3000 System

(2098-DSD-075x-xx and -150x-xx)

Note: Refer to Figure 2.26 in the chapter Ultra3000 Connector Data

for more information on the relay output.

TB1

U

V

W

DC+

DC-

L1

L2

L3

L1 AUX

L2/N AUX

L2

L1

CN1

43

44

L3

TB2

1

2

3

43

44

CN1

43

44

Ultra3000

Digital Servo Drives

2098-DSD-075x-xx and

-150x-xx

Note 13

AC Input Power

Connections

Motor Power

Connections

Three-Phase

AC Line Filter

Note 7

Input Fusing*

Note 4, 5

Three-Phase Input

100-240V ac RMS

Fused Disconnect

or Circuit Breaker*

Note 1

Isolation

Transformer*

Note 2

Chassis

Bonded Cabinet

Ground Bus*

Terminal

Blocks*

Note 3

To additional

Ultra3000 drive

Three-Phase

Motor Power

Connections

Note 12

Cable Shield

Clamp

Note 9

* INDICATES USER-SUPPLIED COMPONENT

STOP*

START*

CR1*

CR1*

CR1*

M1*

Refer to Attention statement (Notes 10, 11)

N.O. Relay Output+

N.O. Relay Output-

Note 20

24V dc

Neutral

Note 6

M1*

Note 8

External Passive

Shunt Connections

(refer to figures

beginning on B-7)

Three-Phase AC Line

50/60 Hz