Page b-15 – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 15

Advertising
background image

Publication 2098-DU003B-EN-P — September 2006

Ultra3000 Digital Servo Drive Installation Manual

11

Page B-15

Replace Figure B.15 on page B-15 with the one shown below. The
new figure correctly identifies the motor power-cable pins as 1, 2, 3,
and 5. Also included is an illustration of grounding the feedback cable
shield.

Figure B.15
Ultra3000 Drive to Y-Series (230V) Motors

5

3

2

1

BR+

BR-

7

9

W

V

U

AM+

AM-

BM+

BM-

IM+

IM-

S1
S2

GREEN

WHT/GREEN

BLACK

WHT/BLACK

RED

WHT/RED

1
2

3
4

14

6

5

10

GRAY

WHT/GRAY

12
13

8

S3

WHT/BLUE

BLUE

BROWN

WHT/BROWN

22
23
24

9

10

11
12

13
14

15
17

19

+5VDC

ECOM

DRAIN

GND

43

44

+24V

COM

1-BLK

2-BLK

3-BLK

GN/YL

U

V

W

Motor
Brake

Motor

Power

TB1

Cable Shield
Clamp

Note 9

Note 19

Motor Feedback

(15-pin) Connector

CN2

Three-Phase
Motor Power

Motor

Feedback

User Supplied

+24V dc Power Supply

(1.0 A max)

2090-XXNFY-Sxx (flying lead)

or 2090-UXNFBY-Sxx (with drive-end connector)

Feedback Cable

Notes 12, 15, 16

Motor Feedback
(CN2) Connector

2090-XXNPY-16Sxx
Motor Power Cable

Note 12

Ultra3000 230V Drive

Note 13

BLK

BLK

Control Interface

(44-pin) Connector

CN1

Green/Yellow

3/Black

2/Black

1/Black

Y-Series (230V)

Servo Motors with

Incremental Feedback

Pigtail

Pigtail

Refer to illustration (lower left)

for proper grounding technique.

Motor Feedback Breakout Board

(2090-UXBB-DM15)

Grounding Technique for

Feedback Cable Shield

Exposed shield secured

under clamp.

Cable Tie

Advertising
This manual is related to the following products: