Connecting Your Ultra3000

Connecting Motor Power
and Brakes

This procedure assumes you have wired your input power and are
ready to wire the motor power and brake connections.

Refer to Appendix B for the power wiring diagram for your Ultra3000.

Applying the Motor Cable Shield Clamp

To apply the motor power cable shield clamp:

1. Loosen the two screws securing the cable clamp on the Ultra3000

drive (refer to figures 3.11 or 3.12 for the cable clamp location on
your Ultra3000 drive).

2. Feed the cable into the clamp and position the exposed portion of

the cable braid directly in line with the clamp.

3. Extend the cable along side the drive leaving an appropriate

length of cable for terminating the motor power wires.

4. Check that the exposed cable braid is still in line with the clamp

(adjust alignment if necessary).

5. Tighten the screws with a torque of 0.9-1.1 Nm (8.0-10.0 lb-in.).

IMPORTANT

When tightening screws to secure the wires, refer to
the table on page 3-13 for torque values.

IMPORTANT

To ensure system performance, run wires and cables
in the wireways as established in Chapter 1.