Publication 2098-IN003E-EN-P — April 2004

Interconnect Diagrams

B-7

Shunt Module Interconnect
Diagrams

This section contains the interconnect diagrams connecting the
Ultra3000 drives with active and passive shunt modules. Refer to
External Shunt Kits in Appendix C for Ultra3000/shunt combinations.

Active Shunt Module Diagrams

In the figure below, the Ultra3000 (2098-DSD-005x-xx, -010x-xx, or
-020x-xx) is shown wired with the 2090-UCSR-A300 active shunt
module.

Figure B.5
External Active Shunt Module Interconnect Diagram

Passive Shunt Module Diagrams

In the Figure B.6, the Ultra3000 is shown wired for internal shunt
operation. This is the factory default jumper setting.

Figure B.6
Internal Shunt Interconnect Diagram

TB1

DC+

DC-

L1

L2/N

DC+

DC-

L1

L2/N

Ultra3000

Digital Servo Drives

2098-DSD-005x-xx,

-010x-xx, and -020x-xx

External Active

Shunt Module

2090-UCSR-A300

DC Bus Connections

for Active Shunt Module

AC Input Power

Connections

IMPORTANT

Internal shunt operation is only present on the drives
listed in the figure below.

TB2

1

2

3

Ultra3000

Digital Servo Drives

2098-DSD-030x-xx,
-075x-xx
, -150x-xx,

-HVxxx-xx, and

-HVxxxX-xx

Internal Passive Shunt

Resistor Connections