Power interconnect diagrams – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 157

Advertising
background image

Publication 2098-IN003E-EN-P — April 2004

Interconnect Diagrams

B-3

Power Interconnect
Diagrams

The Ultra3000 (2098-DSD-005x-xx, -010x-xx, and -020x-xx) power
wiring with 24V dc control string (non-SERCOS drives only) is shown
in the figure below. To avoid a separate 5V dc auxiliary logic power
supply, the 24V to 5V converter breakout board (2090-U3CBB-DMxx)
is used to wire the control interface (CN1) connector. For the control
string diagram with 120V ac input refer to Figure B.16.

For SERCOS drives, input line contactor is part of the PLC program
and output control.

Figure B.1
Typical Power Wiring of Ultra3000 System

(2098-DSD-005x-xx, -010x-xx, and -020x-xx)

Note: Refer to Figure 2.26 in the chapter Ultra3000 Connector Data

for more information on the relay output.

TB1

DC+

DC-

L1

L2/N

U

V

W

L2/N

L1

CN1

43

44

3

2

43

44

CN1

Ultra3000

Digital Servo Drives

2098-DSD-005x-xx,

-010x-xx, and -020x-xx

Note 13

DC Bus Connections

for Active Shunt Module

(refer to Figure B.5)

AC Input Power

Connections

Motor Power

Connections

M1*

Note 8

Single-Phase
AC Line Filter

Note 7

Input Fusing*

Note 4, 5

Single-Phase AC Line

50/60 Hz

Fused Disconnect

or Circuit Breaker*

Note 1

Isolation

Transformer*

Note 2

Chassis

Bonded Cabinet

Ground Bus*

Terminal

Blocks*

Note 3

To additional

Ultra3000 drive

Three-Phase

Motor Power

Connections

Note 12

Cable Shield

Clamp

Note 9

* INDICATES USER-SUPPLIED COMPONENT

STOP*

START*

CR1*

CR1*

CR1*

M1*

Refer to Attention statement (Notes 10, 11)

24V dc

N.O. Relay Output+

N.O. Relay Output-

Aux Logic Power In +5V

Aux +5V Common

Note 21

Note 20

From CN1 Breakout

Board with 24V to 5V

Aux Power Converter

(2090-U3CBB-DMxx)

Single-Phase Input

100-240V ac RMS

Advertising
This manual is related to the following products: