E03

Absolute Feedback Range Exceeded

The motor position exceeds +/- 2047
revolutions from the home position (applies
only to systems with absolute feedback).

• Decrease application range of motion.
• Upgrade firmware.

E04

Motor Overtemperature

Motor thermostat trips due to:

• High motor ambient temperature

and/or

• Excessive current

• Operate within (not above) the

continuous torque rating for the
ambient temperature (40°C maximum).

• Lower ambient temperature, increase

motor cooling.

Motor wiring error.

Check motor wiring.

Incorrect motor selection.

Verify the proper motor has been selected.

E05

IPMFault

Motor cables shorted.

Verify continuity of motor power cable and
connector.

Motor winding shorted internally.

Disconnect motor power cables from the
motor. If the motor is difficult to turn by
hand, it may need to be replaced.

Ultra3000 temperature too high.

• Check for clogged vents or defective

fan.

• Ensure cooling is not restricted by

insufficient space around the unit.

Operation above continuous power rating.

• Verify ambient temperature is not too

high.

• Operate within the continuous power

rating.

• Reduce acceleration rates.

Ultra3000 has a bad IPM output, short
circuit, or overcurrent.

Remove all power and motor connections,
and preform a continuity check from the DC
bus to the U, V, and W motor outputs. If a
continuity exists, check for wire fibers
between terminals, or send drive in for
repair.

An attempt was made to enable the drive
without waiting at least 1.0 second after
applying the main AC power. Note: This
applies to 2098-DSD-005, -010, and -020
Ultra3000 models only (when using an
external +5V auxiliary power supply).

Wait at least 1.0 second after the main AC
is applied before enabling the drive.

E06

Hardware Overtravel
(SERCOS only)

Dedicated overtravel input is inactive.

• Check wiring.
• Verify motion profile.

E07

RESERVED

Call your local Allen-Bradley
representative.

E08

RESERVED

E09

Bus Undervoltage

Low AC line/AC power input.

• Verify voltage level of the incoming AC

power.

• Check AC power source for glitches or

line drop.