Input interface examples for active high inputs – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 72

Advertising
background image

Publication 2098-IN003E-EN-P — April 2004

2-30

Ultra3000 Connector Data

Input Interface Examples for Active High Inputs

Figure 2.14
Drive Input Connected to Switch/Relay Contact

Figure 2.15
Drive Input Connected to Opto-Isolator

Figure 2.16
Drive Input Connected to NPN Transistor

Ultra3000 Drive

IOPWR

IOPWR

CN1-29

CN1-30

2.7k

Ω

+5V

10k

Ω

1k

Ω

IOCOM

DGND

IOCOM

TLP121

CN1-31

through CN1-38

CN1-29

CN1-30

2.7k

Ω

+5V

10k

Ω

1k

Ω

IOCOM

DGND

IOCOM

TLP121

CN1-31

through CN1-38

Ultra3000 Drive

IOPWR

IOPWR

2.7k

Ω

1k

Ω

IOCOM

CN1-29

CN1-30

Ultra3000 Drive

IOPWR

IOPWR

Advertising