Attention, Ultra3000 – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 172

Advertising
background image

Publication 2098-IN003E-EN-P — April 2004

B-18

Interconnect Diagrams

The 120V ac control string wired to the Ultra3000 (2098-DSD-075x-xx,
-150x-xx, -HVxxx-xx, and -HVxxxX-xx) drives is shown in the figure
below.

Figure B.18
120V ac Three-Phase Control String Example

ATTENTION

!

Implementation of safety circuits and risk assessment
is the responsibility of the machine builder. Please
reference international standards EN1050 and EN954
estimation and safety performance categories. For
more information refer to Understanding the
Machinery Directive
(publication SHB-900).

CN1

Ultra3000

Three-Phase

AC Line

50/60 Hz

M1

U

V

W

+

-

L1

L2

L3

L1

AUX

L2/N

AUX

Motor

DC Bus

100-240 VAC

50/60 Hz

Internal

External

Shunt

1

2

3

TB2

TB1

Fuse

Block

L1
L2
L3

L1 Aux

L2/N Aux

120V AC

50/60 Hz

STOP

START

CR1

CR1

CR1

M1

Refer to Attention statement above

CR2

N.O. Relay Output+

N.O. Relay Output-

43

44

CR2

24V DC

Ultra3000

Note 20

Advertising